Cable Loss & Frequency Filter Calculator

Estimate the signal attenuation and the cut-off (−3 dB) frequency introduced by a transmission cable for voltage-mode, current-mode and IEPE signal chains. Gold fields are inputs.

Cable run SHARED

meters
Ohm/km
Cable resistance (one conductor)
Pick a transmission cable in the Voltage or Current card to auto-fill its datasheet capacitance and resistance. Rc is shared across all modes — the last cable selected sets it.

Voltage mode V

Ohm
kiloOhm
+ shield
pF/m
pF/m
Ohmic loss
Overall capacitance Ctotal
Cable capacity Cc
Cut-off Fv Hz

Current mode I

Ohm
+ shield
pF/m
pF/m
Overall capacitance Ctotal
Cable capacity Cc
Uses cable resistance from cable run
Cut-off Fc Hz

I.E.P.E. mode IEPE

mA
mA
mV/g
g
Remaining current available Ia = Ips − Imin
Cable capacity (from current mode)
Limit Fiepe Hz
Additional slew-rate limit set by the available drive current. The usable bandwidth is the lowest of Fiepe and the current-mode cut-off Fc.
Field to enter (compulsory) Result — cut-off frequency Intermediate result

Cable Transmission Distance Graphs

Maximum frequency of interest transmittable over a given cable distance, from sensor to monitor, for voltage mode, current mode (MPC4) and current mode with a GSI 127 low-impedance input.

Cable & system parameters

Cable presets (datasheet)
Cable (from datasheet)
pF/m
pF/m
Ohm/km
Current transmission
Ohm
Ohm
Voltage transmission
Ohm
Pick a cable preset above to auto-fill its datasheet capacitance and resistance. Cable resistance is shared by all three curves — the last preset chosen sets it.

Maximum frequency of interest vs. distance

Voltage mode (Hz) Current mode (Hz) Current mode w/ GSI (Hz)
Distance (m) Voltage (Hz) Current (Hz) Current w/ GSI (Hz)